1, the valve is not open: In theWater Heater Gas Valvesis opened, there is no fire to boil water, mainly due to a ruptured eardrum outlet nozzle, the valve can not open the top. Remedy is to buy a new eardrum replaced. During the replacement process, to anti-Stop the hollow screws on hold against the eardrum, otherwise, even if replaced with a new drum, the valve can not open the top.
2, ignition unfavorable: Ignition difficulties or misfiring nozzles and the main reason is fire carbon heater, or valve gauze filter fouling. Remedy is to check the fire nozzle and electric heaters, such as found in soot, cleaned; if the valve fouling gauze filter, you can unscrew the inlet pipe, remove the filter gauze washed with water after cleaning the water pipes installed .
3, burning odor: Hose is not connected or there are cracks and leaks, it should be properly installed or replace the hose; oil or debris also easy to cause odor, it should be cleaned or cleared on firearms.
4, combustion is incomplete: incomplete combustion will lead to an increase in harmful gases, serious environmental pollution, mainly because of the heat exchanger and the main burner clogging. Remedy is to check the heat exchanger and the main burner, and washed, so smooth.
5, copper leaks: the most easily damaged is facing long fire place. The main reason is the disruption of water supply, the case of low water pressure or fire for a long time is not long off, the copper wall burn. When emergencies, will be temporarily fuse plug holes. After use, remove the Gas Valve For Water Heater, put the best water in the water, electric iron will leak eye weld. In order to prevent the premises being burned again, you can install the piece of iron on copper, used to block the long flame.
6, heat storage piece fouling: fouling thermal storage piece, it will affect the absorption of heat and ventilation. The main reason is to use a long time, the indoor air does not circulate. Remedy is Huigou remove heat storage sheet between Huigou if too thick, can be ground into a hacksaw blade-shaped ramp, gently scrape the grime clean and scraped with a bicycle pump Huigou blown clean . Also steel blade or other tool storage allocated to the uniform distribution of the heat sink, so as not to affect the storage of heat and ventilation.
7, burning yellow flame: the gas too much pressure relief valve should be replaced; inadequate supply of fresh air to the exhaust fan or open windows and doors immediately change the fresh air; there is debris blocking mix of Aikido and should be cleaned up.
8, no hot water: valve or pipe blockage, to replace valves, check valves and pneumatic piping; water temperature is low, you should turn up the gas supply, transfer a small amount of cold water supply; water control system the failure to invite professional and technical personnel maintenance.